EasyManua.ls Logo

Enterasys SecureStack C2 C2G170-24

Enterasys SecureStack C2 C2G170-24
698 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
set spantree lpwindow
9-48 Spanning Tree Configuration
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoresettheLoopProtecteventthresholdtothedefaultof3:
C2(rw)->clear spantree lpthreshold
set spantree lpwindow
UsethiscommandtosettheLoopProtecteventwindowvalueinseconds.
Syntax
set spantree lpwindow value
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Usage
TheLoopProtectWindowisatimer value,inseconds,thatdefinesa periodduringwhichLoop
Protecteventsarecounted.Thedefaultvalueis180seconds.Ifthetimerissetto0,the event
counterisnotresetuntiltheLoopProtecteventthresholdisreached.Ifthethreshold
isreached,
thatconstitutesaloopprotectionevent.
Example
ThisexampleshowshowtosettheLoopProtecteventwindowto120second s:
C2(rw)->set spantree lpwindow 120
show spantree lpwindow
UsethiscommandtodisplaythecurrentLoopProtecteventwindowvalue.
Syntax
show spantree lpwindow
value Specifiesthenumberofsecondsthatcomprisetheperiodduringwhich
LoopProtecteventsarecounted.Thedefaulteventwindowis180
seconds.

Table of Contents

Other manuals for Enterasys SecureStack C2 C2G170-24

Related product manuals