set rmon alarm properties
15-10 RMON Configuration
set rmon alarm properties
Useî ±thisî ±commandî ±toî ±configureî ±anî ±RMONî ±alarmî ±entry,î ±orî ±toî ±createî ±aî ±newî ±alarmî ±entryî ±withî ±anî ±
unusedî ±alarmî ±indexî ±number.î ±
Syntax
set rmon alarm properties index [interval interval] [object object] [type
{absolute | delta}] [startup {rising | falling | either}] [rthresh rthresh]
[fthresh fthresh] [revent revent] [fevent fevent] [owner owner]
Parameters
Table 15-2 show rmon alarm Output Details
Output Field What It Displays...
Index Index number for this alarm entry.
Owner Text string identifying who configured this entry.
Status Whether this event entry is enabled (valid) or disabled.
Variable MIB object to be monitored.
Sample Type Whether the monitoring method is an absolute or a delta sampling.
Startup Alarm Whether alarm generated when this entry is first enabled is rising, falling, or either.
Interval Interval in seconds at which RMON will conduct sample monitoring.
Rising Threshold Minimum threshold for causing a rising alarm.
Falling Threshold Maximum threshold for causing a falling alarm.
Rising Event Index Index number of the RMON event to be triggered when the rising threshold is
crossed.
Falling Event Index Index number of the RMON event to be triggered when the falling threshold is
crossed.
index Specifiesî ±anî ±indexî ±numberî ±forî ±thisî ±entry.î ±Maximumî ±numberî ±orî ±entriesî ±isî ±
50.î ±Maximumî ±valueî ±isî ±65535.
intervalî ±interval (Optional)î ±Specifiesî ±anî ±intervalî ±(inî ±seconds)î ±forî ±RMONî ±toî ±conductî ±sampleî ±
monitoring.î ±
objectî ±object (Optional)î ±Specifiesî ±aî ±MIBî ±objectî ±toî ±beî ±monitored.
Note: This parameter is not mandatory for executing the command, but
must be specified in order to enable the alarm entry configuration.
typeî ±absoluteî ±|î ±
delta
(Optional)î ±Specifiesî ±theî ±monitoringî ±methodî ±as:î ±samplingî ±theî ±absoluteî ±
valueî ±ofî ±theî ±object,î ±orî ±theî ±differenceî ±(delta)î ±betweenî ±objectî ±samples.

Table of Contents

Other manuals for Enterasys SecureStack C2 C2G170-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 C2G170-24 and is the answer not in the manual?

Enterasys SecureStack C2 C2G170-24 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2 C2G170-24
CategorySwitch
LanguageEnglish

Related product manuals