7-24 Port Configuration
Examples
Thisexampleshowshowtodisplaytheglobalstatusofthelinktrapdetectionfunction:
C2(rw)->show linkflap globalstate
Linkflap feature globally disabled
Thisexampleshowshowtodisplayportsdisabledbylinkflapdetectionduetoaviolation:
C2(rw)->show linkflap downports
Ports currently held DOWN for Linkflap violations:
None.
Thisexampleshowshowtodisplaythelinkflapparameterstable:
C2(rw)->show linkflap parameters
Linkflap Port Settable Parameter Table (X means error occurred)
Port LF Status Actions Threshold Interval Downtime
-------- --------- ------- ---------- ---------- ----------
ge.1.1 disabled ....... 10 5 300
ge.1.2 enabled D..S..T 3 5 300
ge.1.3 disabled ...S..T 10 5 300
Table 73providesanexplanationoftheshowlinkflapparameterscommandoutput.
Thisexampleshowshowtodisplaythelinkflapmetricstable:
C2(rw)->show linkflap metrics
Port LinkStatus CurrentCount TotalCount TimeElapsed Violations
-------- ----------- ------------ ---------- ----------- -------------
ge.1.1 operational 0 0 241437 0
ge.1.2 disabled 4 15 147 5
ge.1.3 operational 3 3 241402 0
Table 74providesanexplanationoftheshowlinkflapmetricscommandoutput.
Table 7-3 show linkflap parameters Output Details
Output Field What it displays...
Port Port designation.
LF Status Link flap enabled state.
Actions Actions to be taken if the port violates allowed link flap behavior.
D = disabled, S = Syslog entry will be generated, T= SNMP trap
will be generated.
Threshold Number of link down transitions necessary to trigger the link flap
action.
Interval Time interval (in seconds) for accumulating link down transitions.
Downtime Interval (in seconds) port(s) will be held down after a link flap
violation.
Table 7-4 show linkflap metrics Output Details
Output Field What it displays...
Port Port designation.
LinkStatus Link status according to the link flap function.
CurrentCount Link down count accruing toward the link flap threshold.
TotalCount Number of link downs since system start,

Table of Contents

Other manuals for Enterasys SecureStack C2 C2G170-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 C2G170-24 and is the answer not in the manual?

Enterasys SecureStack C2 C2G170-24 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2 C2G170-24
CategorySwitch
LanguageEnglish

Related product manuals