set sntp server
14-30 Logging and Network Management
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtocleartheSNTPclient’soperationalmode:
C2(su)->clear sntp client
set sntp server
UsethiscommandtoaddaserverfromwhichtheSNTPclientwillretrievethecurrenttimewhen
operatinginunicastmode.Upto10serverscanbesetasSNTPservers.
Syntax
set sntp server ip-address [precedence]
Parameters
Defaults
Ifprecedenceisnotspecified,1willbeapplied.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtosettheserveratIPaddress10.21.1.100 asan SNTPserver:
C2(su)->set sntp server 10.21.1.100
clear sntp server
UsethiscommandtoremoveoneorallserversfromtheSNTPserverlist.
Syntax
clear sntp server {ip-address | all}
Parameters
Defaults
None.
ipaddress SpecifiestheSNTPserversIPaddress.
precedence (Optional)SpecifiesthisSNTPserversprecedenceinrelationtoitspeers.
Validvaluesare1(highest)to10(lowest).
ipaddress SpecifiestheIPaddressofaservertoremovefromthe SNTPserverlist.
all RemovesallserversfromtheSNTPserverlist.

Table of Contents

Other manuals for Enterasys SecureStack C2 C2G170-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 C2G170-24 and is the answer not in the manual?

Enterasys SecureStack C2 C2G170-24 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2 C2G170-24
CategorySwitch
LanguageEnglish

Related product manuals