EasyManua.ls Logo

Enterasys SecureStack C2 C2G170-24 - Set Port Alias; Show Port Alias

Enterasys SecureStack C2 C2G170-24
698 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
show port alias
7-8 Port Configuration
Mode
Switchcommand,read‐write.
Example
Thisexampleshowshowtoenablege.1.3:
C2(su)->set port enable ge.1.3
show port alias
Usethiscommandtodisplaythealias nameforoneormoreports.
Syntax
show port alias [port-string]
Parameters
Defaults
Ifport‐stringisnotspecified,aliasesforallportswillbedisplayed.
Mode
Switchcommand,read‐only.
Example
Thisexampleshowshowtodisplayaliasinformationforports1‐3onslot3:
C2(rw)->show port alias ge.3.1-3
Port ge.3.1 user
Port ge.3.2 user
Port ge.3.3 Admin
set port alias
Usethiscommandtoassignanaliasnametoaport.
Syntax
set port alias port-string [name]
Parameters
port‐string (Optional)Displaysaliasname(s)forspecificport(s).Foradetailed
descriptionofpossibleport‐stringvalues,referto“PortSt ringSyntax
UsedintheCLI”onpage7‐2.
port‐string Specifiestheporttowhichanaliaswillbeassigned.Foradetailed
descriptionofpossibleport‐stringvalues,referto“PortStringSyntax
UsedintheCLI”onpage7‐2.
name (Optional)Assignsanaliasnametotheport.Ifthealiasnamecontains
spaces,thetext
stringmustbesurroundedbydoublequotes.Maximum
lengthis60characters.

Table of Contents