Loading...
set garp timer
SecureStack C2 Configuration Guide 10-25
Defaults
None.
Mode
Switchcommand,readwrite.
Usage
Thesettingofthesetimersiscriticalandshouldonlybechangedby personnelfamiliarwiththe
802.1Qstandardsdocumentation,whichisnotsuppliedwiththisdevice.
Examples
ThisexampleshowshowtosettheGARPjointimervalueto100centisecondsforallports:
C2(su)->set garp timer join 100 *.*.*
Thisexampleshowshowtosettheleavetimervalueto300centisecondsforallports:
C2(su)->set garp timer leave 300 *.*.*
Thisexampleshowshowtosettheleavealltimervalueto20000centisecondsforallports:
C2(su)->set garp timer leaveall 20000 *.*.*
leavealltimer
value
SetstheGARPleavealltimerincentiseconds(Referto802.1Qstandard.)
portstring Specifiestheport(s)onwhichtoconfigureGARPtimersettings.Fora
detaileddescriptionofpossibleportstringvalues,refertoPortString
SyntaxUsedintheCLIonpage 72.