Table B-2. LTO Tape Drive Sense Data (continued)
Byte
Bit Address or Name
76543210
12-13 Sense Key 6 (Unit Attention)
EE 12 - Encryption - Key Change Detected
EE 18 - Encryption - Changed (Read)
EE 19 - Encryption - Changed (Write)
EE 40 - Encryption - EKM Identifier Changed
EE 41 - Encryption - EKM Challenge Changed
EE 50 - Encryption - Initiator Identifier Changed
EE 51 - Encryption - Initiator Response Changed
2A 11 - Encryption - Data Encryption Parameters Changed by Another I_T Nexus
2A 12 - Encryption - Data Encryption Parameters Changed by Vendor Specific Event
Sense Key 7 (Data Protect)
EF 10 - Encryption - Key Required
EF 11 - Encryption - Key Generation
EF 13 - Encryption - Key Translate
EF 1A - Encryption - Key Optional
EF C0 - Encryption - No Operation
26 10 - Encryption - Data Decryption Key Fail Limit
2A 13 - Encryption - Data Encryption Key Instance Counter Has Changed
74 00 - Security Error
74 01 - Encryption - Unable to Decrypt Data
74 02 - Encryption - Unencrypted Data Encountered While Decrypting
74 03 - Encryption - Incorrect Data Encryption Key
74 04 - Encryption - Cryptographic Integrity Validation Failed
74 05 - Encryption - Error Decrypting Data
14 FRU code
15 SKSV C/D Reserved BPV
When set to
1, the bit
pointer is
valid.
Bit pointer
16 -17 SKSV = 0: First Error Fault Symptom Code (FSC).
SKSV = 1: Field Pointer
18-19 First Error Flag Data
20 Reserved (0)
21 CLN Reserved Reserved VolValid
22-28 Volume Label
29 Current Wrap
30-33 Relative LPOS
34 SCSI Address
35 Frame number Drive number
The descriptions below serve only as an overview of sense reporting in the tape
drive. This tape drive conforms to all sense field reporting as specified in the SCSI
standards.
Note:
Appendix B. Sense Data B-11