EasyManuals Logo

IBM TS3310 User Manual

IBM TS3310
531 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #408 background imageLoading...
Page #408 background image
1. The Error Code field (Byte 0) is set to 70h to indicate a current error,
that is one associated with the most recently received command. It is
set to 71h to indicate a deferred error which is not associated with the
current command.
2. The segment number (Byte 1) is zero since the Copy, Compare, and
Copy and Verify commands are not supported.
3. The File Mark flag (Byte 2, bit 7) is set if a Space, Read, or Verify
command did not complete because a file mark was read.
4. The End of Media (EOM) flag (Byte 2, bit 6) is set if a Write or Write
File Marks command completed in the early warning area. Spacing into
BOM also causes this flag to be set. It is also set on an attempt to read
or space past EOD, or if an attempt is made to space into Beginning of
Media.
5. The Illegal Length Indicator (ILI) flag (Byte 2, bit 5) is set if a Read or
Verify ended because a block was read from tape that did not have the
block length requested in the command.
6. The Information Bytes (Bytes 3-5) are only valid if the Valid flag is set.
This occurs only for current errors and not for deferred errors.
7. The Field Replaceable Unit field (Byte 14) is set to either zero or to a
non-zero, vendor-specific code indicating which part of the drive is
suspected of causing the failure.
8. The Clean (CLN) flag (Byte 21, bit 3) is set if the drive needs cleaning
and clear otherwise.
9. The Volume Label Fields Valid (VolValid) bit (Byte 21, bit 0) is set if the
Volume Label being reported is valid.
10. The Volume Label field (Bytes 22-28) reports the volume label if a
cartridge is loaded in the drive and Volume Label Fields Valid is set.
11. The Current Wrap field (Byte 29) reports the physical wrap of the tape.
The least significant bit reflects the current physical direction. A 0
means that the current direction is away from the physical beginning of
the tape. A 1 means that the current direction is towards the physical
beginning of the tape.
12. Relative LPOS fields (Bytes 30-33) reports the current physical position
on the tape.
13. SCSI Address field (Byte 34) reports the SCSI Bus Address for the drive.
Values returned range from 00h to 0Fh.
14. This field (Byte 35) contains the frame and drive number, passed across
the RS-422 serial interface.
B-12 TS3310 Tape Library Maintenance Information

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM TS3310 and is the answer not in the manual?

IBM TS3310 Specifications

General IconGeneral
Form FactorRack-mountable
Tape TechnologyLTO Ultrium
Product TypeTape Library
InterfaceFibre Channel
ExpansionExpandable with additional modules
Supported Tape TechnologyLTO Ultrium 5, LTO Ultrium 6
Weight120 lb (54.4 kg) (fully configured)
Power SupplyDual redundant power supplies
Operating Temperature41°F to 95°F (5°C to 35°C)
Non-operating Temperature-40°F to 140°F (-40°C to 60°C)
Humidity20% to 80% non-condensing

Related product manuals