Table F-2. Status Traps (continued)
Event Trap ID Description
Robotics Not Ready 107 Indicates the library robotics system has transitioned from
"ready" to "not ready". Traps 106 and 107 may occur as part of
a startup or shutdown procedure. If they occur at another
time, a library door may be open.
Logical Library State
Change
108 Indicates whether a logical library has been taken online or
offline.
RAS Status Change:
Connectivity
109 Indicates that the status of the connectivity subsystem (which
includes the I/O management unit and other components) has
changed. This may indicate a change to "good" status, so refer
to the return value to determine what action you should take.
If the return value indicates that a problem exists, use the
Operator Panel or Web UI to determine how to resolve the
issue.
RAS Status Change:
Control
110 Indicates that the status of the control subsystem (which
includes system firmware, the operator panel, and the Library
Control Blade) has changed. If the return value indicates that
a problem exists, use the Operator Panel or Web UI to
determine how to resolve the issue.
RAS Status Change:
Cooling
111 Indicates that the status of the cooling subsystem has changed.
If the return value indicates that a problem exists, use the
Operator Panel or Web UI to determine how to resolve the
issue.
RAS Status Change:
Drives
112 Indicates that the status of the drives and/or media has
changed. If the return value indicates that a problem exists,
use the Operator Panel or Web UI to determine how to resolve
the issue.
RAS Status Change:
Media
113 Indicates that the status of the media has changed. If the
return value indicates that a problem exists, use the Operator
Panel or Web UI to determine how to resolve the issue.
RAS Status Change:
Power
114 Indicates that the status of the power subsystem has changed.
If the return value indicates that a problem exists, use the
Operator Panel or Web UI to determine how to resolve the
issue.
RAS Status Change:
Robotics
115 Indicates that the status of the robotics subsystem has
changed. If the return value indicates that a problem exists,
use the Operator Panel or Web UI to determine how to resolve
the issue.
Operator Intervention
Required
116 An error has occurred, resulting in an Operator Intervention
message. Use the Operator Panel or Web UI to determine how
to resolve the issue.
Drive Online State
Change
117 Indicates that a tape drive has been taken online or offline.
Drive Communication
Failure
121 The library set TapeAlert 1, indicating a drive communication
failure.
Library Hardware Failure 122 The library set TapeAlert 2, indicating a library hardware
failure.
Non-mechanical
Hardware Failure
124 The library set TapeAlert 4, indicating a non-mechanical
hardware failure.
Cartridge Pick Problem 133 The library set TapeAlert 13, indicating a problem when
picking a tape cartridge.
F-2 TS3310 Tape Library Maintenance Information
|
|||
|||
|
|
|
|
|
||
|
|
|
||
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
||
|
|
||
|
|||
|
|
|
||
|
|||
|

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM TS3310 and is the answer not in the manual?

IBM TS3310 Specifications

General IconGeneral
Form FactorRack-mountable
Tape TechnologyLTO Ultrium
Product TypeTape Library
InterfaceFibre Channel
ExpansionExpandable with additional modules
Supported Tape TechnologyLTO Ultrium 5, LTO Ultrium 6
Weight120 lb (54.4 kg) (fully configured)
Power SupplyDual redundant power supplies
Operating Temperature41°F to 95°F (5°C to 35°C)
Non-operating Temperature-40°F to 140°F (-40°C to 60°C)
Humidity20% to 80% non-condensing