Appendix A
A-132 MIPS R4000 Microprocessor User's Manual
Exceptions:
TLB refill exception
TLB invalid exception
TLB modification exception
Bus error exception
Address error exception
Coprocessor unusable exception
Opcode Bit Encoding:
(continued)
SDCz
Store Doubleword
SDCz
From Coprocessor
SDCz
111011
31 30 29 28 27 26
Bit #
0
SDC1
111101
31 30 29 28 27 26
Bit #
0
SDC2
Coprocessor Unit Number
SD opcode