2. Watch the CBMOD's seven-segment display: this allows you to observe the individual steps of
the system boot (Table 5-4).
The CPU is tested after the system starts. All LED segments of the seven-segment display are
activated by hardware default. If a decimal point is visible following the CPU test, an error has
occurred.
For example, if an error is detected during the RAM test, a "2" with a decimal point appears
permanently in the display. If this occurs, the CBMOD board should be replaced.
OfficePro LED status display
The CBMOD central board is equipped with two LEDs that indicate the status of the board and of the
integrated analog modem.
CBMOD status display
Table 5-2 CBMOD - board status display
RUN LED
(green)
Function
off No power
on Power on, Reset switch pressed
off Power on, Reset switch held down for longer than 5 seconds (LED goes out to confirm
that a reload has been started)
on System boot
flashing Normal operating state
Integrated modem status display
Table 5-3 CBMOD - status display for the
integrated modem
IMOD LED
(green)
Function
off No integrated modem is installed
on Integrated modem is ready
flashing Data traffic via integrated modem
Modem access via B channel is also supported. The IMOD LED does not provide a status
display for this type of modem.
Displays during the system boot
Table 5-4 CBMOD - seven-segment display during the system boot
Display Explanation
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_5m.htm (2 of 7) [06/04/2000 13:06:35]