22 18 Signal key (recall), 1 = 1 press/2 = 2 press
22 19 Authorizations
22 19 1 Night service, pos. 1-5, enter extension
22 19 2 Lock all phones
22 19 3 Silent monitor (USA only)
22 20 Automatic DTMF, 0=no/1= yes
22 21 Key click, 0=off/1= volume 1 to 4 = volume 4
22 22 DTMF mark/space, 1 = 70/70 ms / 2 = 80/80 ms /
3 = 80/250 ms / 4 = 200/200 ms
22 23 Phone lock destination
22 24 Relocate procedure, 0 = denied/1 = allowed
22 25 Trunk reservation, 0 = off/1 = on
22 32 Closed DTMF, 0 = off/1 = on
23 Trunk access codes
23 1 Replacement code *, code 75
23 2 Replacement code #, code 76
23 3 Line code, select slot/line and enter new code
23 4 Route code, select route, then position1-10 of the code and enter the new code
Route 1-8 (OfficePoint)
Route 1-16 (OfficeCom/OfficePro)
23 5 Attendant code
23 5 1 Attendant code DID
23 5 2 Attendant code internal
23 6 Second trunk access code
24 Doorphone setup
24 1 Doorphone CM, select door, max. 6 digits, door 1-4
24 2 Doorbell CM, select door, max. 6 digits, door 1-4
24 3 Open door, select door, 0 = not available/1 = available
2= available with DTMF,door 1-4
24 4 Doorphone forward, external, select door, 0 = internal only/1 = full access
24 5 Door release,DTMF, select extension, 0 = denied/1 = allowed
25 Announcement device
25 1 Announcement device, select announcement device,
1 for OfficePoint,
1 to 4 for OfficeCom,
1 to 16 for OfficePro
25 2 Announcement type, select announcement type, 1 = announcement/2 = internal
music on hold /3 = Internal MOH
25 3 Announcement before answer, select slot/line