3-65
3
Note Recycler Configuration
Log In > Configuration Menu > Edit Configuration > Device Configuration > Note Recycler
Allow Note Refusals
This function does not apply to TR250 Series equipment at this time.
Cassette Configuration
The function type can be changed (recycle or deposit), for Cassette 1-4).
Cassette “A” (front most cassette) is reserved for deposit only.
Cassette Pad Percentage
Determines the number of notes (or percentage of notes) that are required to remain in
the specified cassette when a “Prepare Deposit” is performed.
LAN Connection
IP Address Entry = Device addressing (if applicable)
Local = Note Recycler is connected directly to the TR Series computer.
No Device = TR Series will not contain any note recycling menus.
Simulator = Allows the manufacturer to perform testing when a Coin Recycler is not
actually connected to the TR Series (not for field use).
Max Dispense Bundle Size
Determines the number of notes deposited into the note collection area during dispense
transaction.
If the number of notes required to complete the transaction exceeds this number, the
bundled notes will be presented and additional dispense operations will (automatically)
be performed to complete the requested dispense amount.
Note Recycler
G750 = Tidel TR Series Note Recycler (Fujitsu G750)
CI50 = Glory CI50
CI100 = Glory CI100
CI200 = Glory CI200
CI300 = Glory CI300
None = No Note Recycling menus will be available.
Send All Rejects To Deposit
If enabled, all rejected notes (during Dispense and deposit operations) will be placed in
the Deposit Cassette.
This feature can be used to prohibit use of the Reject Cassette.
Note Recycler Serial #
Log In > Configuration Menu > Edit Configuration
Note Handler Serial # entry
Offline End Time
Log In > Configuration Menu > Edit Configuration > User Interface
Determines the time of day the unit will exit the OFFLINE mode (User will be able to perform
functions normally).