2-8
2
Initial Start-up
Apply VAC power to the unit.
f Press and hold the UPS device ON/OFF switch for (2) seconds (if equipped)
The UPS is located at the top/rear/left side of the TR253 Coin Handler
f The ON/OFF switch is located at the top/rear side of the TR250 Note Handler.
When power is applied:
The Main Screen may display errors, due to incomplete setup parameters - Errors can be
ignored, proceed with functionality checks.
Default Set-up (USA)
When the TR250 Series units are shipped from Tidel, the default Log In code is set to 1-2-3-4-5-6.
Tidel recommends the default code be changed AFTER the initial setup of the TR250 Series units
has been completed.
Unless otherwise specified by the Customer, the default setup of the TR250 Series cash devices
were:
Note Recycler Cassettes:
Cassette A = Deposit only
Cassette 1 = Recycle (20.00)
Cassette 2 = Recycle (10.00)
Cassette 3 = Recycle (5.00)
Cassette 4 = Recycle (1.00)
Coin Hoppers:
Hopper 1 = .01
Hopper 2 = .05
Hopper 3 = .10
Hopper 4 = .25
Hopper 5 = N/A
Hopper 6 = Reject Bin (or .50)
Hopper 7 = 1.00
Hopper 8 = N/A
Note
Hopper denominations and positions cannot be changed
without modification to the TR253 Coin Handler components
Register Drawer ID Decals
If the Tidel TR250 is equipped with a Register Drawer Scanner, apply the ID decals to the Cash
Register Drawers.
Safe Fund (Static Balance) Amount
This setting determines what amount will be left in the TR250 after a “Prepare Deposit” is
performed.
Log In > Configuration Menu > Edit Configuration > Courier Options > Static Balance
The STATIC BALANCE may include the amounts in the Coin Hoppers, however, only notes will be
transferred to the Deposit Cassette - No coins will be dispensed or transferred.
Preparing a deposit will cause the Note Recycler to move notes from the Recycle Cassettes to the
Deposit Cassette in order to achieve the Static Balance amount in the TR250.