4-7
4
Note Recycler Vault is unsecure - Please Secure the Note Recycler Door
1) Insure the Note Recycler Door is shut and the Handle is in the locked position.
2) Insure the Combination Lock is in the locked position.
3) Perform a power reset, (place the ON/OFF switch in the OFF position for 30 seconds minimum).
Prior to disconnecting VAC power from the Note Handler/UPS, perform a “Shut Down
Computer”.
Log In > Exit > Shut Down Computer
4) Insure the Solenoid Plunger moves freely.
5) Log into the Door Diagnostic menu and block/unblock the sensors to check operation.
Log In > More > Maintenance > Diagnostics > Doors
6) Check the connection at the Vault Door Locking Bolt Position Sensor.
7) Check the connection at Solenoid Plunger position Sensor.
8) Check the connections at terminal J42 and J43 on the Distribution PCB.
9) Replace the suspected defective Sensor.
10) Replace the Distribution PCB.
Note Recycler Vault is unsecure - Please Secure the Note Recycler Door
1) Insure the Note Recycler Door is shut and the Handle is in the locked position.
2) Insure the Combination Lock is in the locked position.
3) Perform a power reset.
Prior to disconnecting VAC power from the Note Handler/UPS, perform a “Shut Down
Computer”.
Log In > Exit > Shut Down Computer
4) Insure the Solenoid Plunger moves freely.
5) Log into the Door Diagnostic menu and block/unblock the sensors to check operation.
Log In > More > Maintenance > Diagnostics > Doors
6) Check the connection at the Vault Door Locking Bolt Position Sensor.
7) Check the connection at Solenoid Plunger position Sensor.
8) Check the connections at terminal J42 and J43 on the Distribution PCB.
9) Replace the suspected defective Sensor.
10) Replace the Distribution PCB.