13-23
13
Led is not illuminated on Dispenser PCB (all Dispensers)
Magazine not present
1) Ensure the ON/OFF switch is in the ON position.
2) Ensure there is VAC power at the Power Cord.
3) Check all connections on the Rolled Coin Dispenser PCB.
4) Check the +12 VDC output of the Power Supply.
If incorrect, adjust the +12 VDC or replace the Power Supply
5) If voltage is correct, check the voltage at the +5 VDC and +12 VDC test points on the Rolled Coin
Dispenser PCB.
If incorrect, replace the Rolled Coin Dispenser PCB
6) Check the Voltage Present and Health LED’s on the Rolled Coin Dispenser PCB
If not illuminated, the Rolled Coin Dispenser PCB may be defective
7) Possible defective Rolled Coin Dispenser PCB.
Magazine X Disabled
1) Disconnect VAC power from the Controller and Remote Module for a minimum of 1 minute then
re-apply VAC power,
2) One or more of the Dispensers are programmed incorrectly in the Setup Dispenser Menu.
Log In > Cash Control > Configure Dispense Choices > Rolled Coin Dispenser > Setup
Dispensers
Rolled Coin Dispenser Troubleshooting