5
Sensors
The TR250 Note Handler Vault Door is equipped with (2) infrared sensors.
All TR250 Vault Door Sensors are interchangeable.
Note Recycler Vault Door Sensors:
f Door Position Sensor
The sensor the detects the door is completely shut - located at the top of the door.
f Door Lock Sensor
The sensor that detects when Solenoid Plunger is in the (down), locked position
Solenoids
All TR250 Solenoids operate on +24 VDC and are interchangeable.
The Solenoid is activated with +24 VDC and then pulsed with +12 VDC to keep the Solenoid Plunger
retracted, but prevent overheating
If checking voltages at the Solenoid, when activated, the voltmeter will quickly display 14 ~ 24 VDC, then
drop to approximately +3 VDC ~ +5 VDC (indicates normal functionality).
If the Note Handler Vault Door Solenoid is inoperable, the combination lock can be used to raise the
plunger, allowing the door to be opened.
Drilling the Note Handler vault door should not be necessary unless the Solenoid and Combination
Lock are both inoperable.
Sensors and Solenoids
Note Handler Vault
Door Lock Sensor
Note Handler Vault
Door Position Sensor
Note Handler Vault
Solenoid