11-46
11
Note Recycler Self Test
Note Recycler Self Test
NOTE: The Note Recycler and Cassette Rack must be seated fully into the cradle in order to perform the
following test.
Step 1: Extend the Door Switch plunger fully out.
Step 2: Lift the Bill Insertion Coverplate.
Step 3: Disconnect the USB Data Cable from the Note Recycler Interface PCB.
Step 4: Run the Mechanical Reset “Self Test”.
a) Press and hold the SW1, SW2 and ST buttons on the Dispenser PCB.
b) When the LED’s indicate “0.0.”, release all three buttons.
c) Press SW1 until the LED’s indicate “1.0.”
d) Press SW2 until the LED’s indicate “1.1.”
e) Press the ST button twice.
X The Note Recycler should run
Step 5: If no error codes are displayed, disconnect VAC power and reconnect the USB data cable to the Note
Recycler Interface PCB.