To find the end of the tape inside the cartridge, refer to Figure D-14 and perform the steps
below.
1. Attach the cartridge manual rewind tool (1) to the cartridge's hub (2) by fitting the
tool's teeth between the teeth of the hub. Turn the tool clockwise until you see the end
of the tape inside the cartridge. Then, slowly turn the rewind tool counterclockwise to
bring the tape edge toward the cartridge door (3).
2. Continue to turn the rewind tool counterclockwise until approximately 13 cm (5 in.) of
tape hangs from the cartridge door. If necessary, grasp the tape and pull gently to
unwind it from the cartridge.
3. Remove the rewind tool by pulling it away from the cartridge. Set the tool and the
cartridge aside.
Figure D-14. Winding the tape out of the cartridge
To remove the C-clip from the leader pin, refer to Figure D-15 and perform the steps below.
1. On the leader pin (1), locate the open side of the C-clip (2). The C-clip is a small
black part that secures the tape (3) to the pin.
2. Remove the C-clip from the leader pin by using your fingers to push the clip away
from the pin. Set the pin aside and discard the clip.
A67E0036
1
2
3
Figure D-15. Removing the C-clip from the leader pin
D-24 TS3310 Tape Library Maintenance Information

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM TS3310 and is the answer not in the manual?

IBM TS3310 Specifications

General IconGeneral
Form FactorRack-mountable
Tape TechnologyLTO Ultrium
Product TypeTape Library
InterfaceFibre Channel
ExpansionExpandable with additional modules
Supported Tape TechnologyLTO Ultrium 5, LTO Ultrium 6
Weight120 lb (54.4 kg) (fully configured)
Power SupplyDual redundant power supplies
Operating Temperature41°F to 95°F (5°C to 35°C)
Non-operating Temperature-40°F to 140°F (-40°C to 60°C)
Humidity20% to 80% non-condensing