Administration
SNTP and Time Settings
Cisco Small Business 200E Series Advanced Smart Switch Command Reference 100
2
Syntax Descriptions
Default
No summertime offset is configured.
Command Modes
Global Config
Examples
The following example configures a summertime date starting on March 14, 2010
at 2:00 A.M, with an offset of 1 hour, ending on November 7, 2010 at 2:00 A.M. This
example also names this timezone EDT.
(Switch) (Config)#clock summer-time date 14 mar 2010 02:00 7 nov 2010 02:00
offset 60 zone EDT
Related Commands
Parameter Description
date The day of the month when DST begins. The range is 1–31.
month The month when DST begins, specified as the first three
letters by name. For example, enter jan for January.
year The current year. The range is 2000–2097.
hh:mm The time in hours and minutes. The range for hh is 0–23
and the range for mm is 0–59.
offset Number of minutes to add during the summertime. The
range is 1–1440 minutes.
zone acronym An acronym for the local timezone during DST, up to four
characters. The acronym is for display purposes only.
Command Description
clock
summertime
recurring
Sets the summertime offset to UTC recursively every year.
show clock Displays the time and date from the system clock.