Administration
PoE
Cisco Small Business 200E Series Advanced Smart Switch Command Reference 48
2
poe reset
Use this command to enable PoE to reinitialize automatically upon encountering a
fault condition. If this is disabled, then administrator intervention is required to
reinitialize the port. A fault condition is reported by the PoE controller in PSE Port
Detection Status parameter. The possible fault conditions are Fault and Other
Fault. Use the no form of the command to remove automatic reinitialization on a
port.
NOTE The command can be used in Global Config mode to configure all ports and can be
used in Interface mode to configure a specific port.
poe reset
no poe reset
Modes
Global Config
Interface Config
Default
PoE auto-reset is enabled.
Command Description
poe power
management
Sets the power management as dynamic or static.
poe power limit Sets the method for power management.
poe priority Configures the port priority level for the delivery of power
to an attached device.
poe
usagethreshold
Configures the system power usage threshold level at
which a trap is generated and a message is logged.
show poe Displays the global configuration, and information about
each device connected to the PSE port(s).
show poe port
configuration
Displays per-port PoE configuration.
show poe port Displays per-port PoE status.