The header for long output format (Figure 7-3) is output in the language used system-wide.
After 62 lines have been printed (incl. header) a form feed is executed (FF) and printing
resumes on the next page with a header.
Figure 7-3 Long output format for call data
Table 7-2 Long output format - explanation of output fields
Field Fields Definition Number of
characters
Alignment
Datum 1 to 8 see Table 7-1, field position 1 8 Left
Time 10 to 17 see Table 7-1, field position 2 8 Left
Trk 19 to 21 see Table 7-1, field position 3 3 Right
Stn 23 to 28 see Table 7-1, field position 4 6 Right
Call 30 to 34 see Table 7-1, field position 5 6 Left
Duration 36 to 43 see Table 7-1, field position 6 8 Left
Ext
number
45 to 64 Dialled or, if available, received external
station number: nnnnnnnnnnnnnnnnnnnn
(n = dialled or received character: value
range 0 ... 9, *, #, ?)
see also Table 7-1, field position 7
20 Left
Amount 66 to 76 Call charge amount for a call segment:
zzzzzzzzzzz
(z = digit: value range 0 ... 9)
This is always output when call charges
accrue for a call segment (e.g. also for
transferred calls). If call charge information
is not available, the 11 positions are filled
with blanks. Decimal places are separated by
a "decimal point" (.).
11 Right
I 78 to 79 see Table 7-1, field position 9 2 Right
- 80 to 81 End-of-line control characters
(Carriage Return CR, Line Feed LF)
2 -
Hicom 150 E Office Rel.1.0 Service Manual - 7.12 Features for Call Detail Recording
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_712.htm (19 of 21) [06/04/2000 13:08:19]