Hex Code
Generic
Scan Tool
Code
DRB Scan Tool Display Description of Diagnostic Trouble Code
82 P0160 2/2 O2S Stays at Center
Neither rich or lean condition detected from the
downstream oxygen sensor.
84 P0121
TPS Voltage Does Not Agree
With MAP
TPS signal does not correlate to MAP sensor.
89 P0700 EATX Controller DTC Present
An automatic transmission input DTC has been
set in the transmission controller. Refer to Group
21.
91 P1299
Vacuum Leak Found (IAC
Fully Seated)
MAP sensor signal does correlate to TPS signal.
Possible vacuum leak.
92 P1496 5 Volt Supply Output Too Low
5 volt output from regulator does not meet
minimum requirement.
99 P1493
Ambient/Batt Temp Sen Volts
Too Low
Battery temperature sensor input voltage below
an acceptable range.
9A P1492
Ambient/Batt Temp Sensor
Volts Too High
Battery temperature sensor input voltage above
an acceptable range.
9B P0131 1/1 O2S Shorted to Ground O2 sensor voltage too low, tested after cold start.
9C P0137 1/2 O2S Shorted to Ground O2 sensor voltage too low, tested after cold start.
9D P1391
Intermittent Loss of CMP or
CKP
Intermittent loss of either camshaft or crankshaft
position sensor.
B5 P0151 2/1 O2S Shorted to Ground O2 sensor voltage too low, tested after cold start.
B6 P0157 2/2 O2S Shorted to Ground O2 sensor voltage too low, tested after cold start.
D8 P0356 Ignition coil #6 ckt
Peak primary circuit current not achieved with
max. dwell time.
D9 P1288 Short run valve ckt
An open or shorted condition detected in the SRV
tuning circuit.
25 - 6 EMISSION CONTROL SYSTEMS LH
DESCRIPTION AND OPERATION (Continued)