EasyManua.ls Logo

Rohde & Schwarz R&S ZNA Series - 7.3.1.5 CALCulate:FILTer[:GATE]...

Rohde & Schwarz R&S ZNA Series
1849 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command reference
R&S
®
ZNA
1012User Manual 1178.6462.02 ─ 29
Parameters:
<EyeView> STIMulus | EMPHasis | JITTer | NOISe | DUT | EQUalization
The rightmost building block that shall be part of the calculation
chain STIMulus > EMPHasis > JITTer > NOISe > DUT > EQUali-
zation.
Note that the selected block must be active, for example
CALCulate1:EYE:VIEW JITTER requires
CALCulate<Chn>:EYE:JITTer:STATe to be ON.
Conversely, if CALCulate1:EYE:VIEW is set to JITTER and
subsequently CALCulate1:EYE:JITTer:STATe is turned
OFF, the calculation chain is further shortened to the next active
building block.
Options:
R&S ZNA-K20
Manual operation: See "[Slider]" on page 813
7.3.1.5 CALCulate:FILTer[:GATE]...
The CALCulate:FILTer[:GATE]... commands define the properties of the time
gate which is used to optimize the time domain response.
CALCulate:FILTer[:GATE]:TIME:AOFFset....................................................................... 1012
CALCulate<Chn>:FILTer[:GATE]:TIME:CENTer...............................................................1013
CALCulate<Chn>:FILTer[:GATE]:TIME:DCHebyshev....................................................... 1013
CALCulate<Chn>:FILTer[:GATE]:TIME:LINK................................................................... 1014
CALCulate<Chn>:FILTer[:GATE]:TIME:SHAPe................................................................1014
CALCulate<Chn>:FILTer[:GATE]:TIME:SHOW................................................................ 1015
CALCulate<Chn>:FILTer[:GATE]:TIME:SPAN..................................................................1015
CALCulate<Chn>:FILTer[:GATE]:TIME:STARt.................................................................1015
CALCulate<Chn>:FILTer[:GATE]:TIME:STOP................................................................. 1015
CALCulate<Chn>:FILTer[:GATE]:TIME:STATe................................................................. 1016
CALCulate<Chn>:FILTer[:GATE]:TIME[:TYPE]................................................................ 1016
CALCulate<Chn>:FILTer[:GATE]:TIME:WINDow............................................................. 1017
CALCulate:FILTer[:GATE]:TIME:AOFFset <Boolean>
Activates the operating mode where the time gate is moved in the opposite direction
when the "Delay" setting is changed.
Parameters:
<Boolean> ON | OFF - enable or disable "Adjust Time Gate".
*RST: OFF
SCPI command reference

Table of Contents

Related product manuals