EasyManua.ls Logo

Rohde & Schwarz R&S ZNA Series - 7.3.14.17 [SENSe:]POWer...

Rohde & Schwarz R&S ZNA Series
1849 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command reference
R&S
®
ZNA
1463User Manual 1178.6462.02 ─ 29
7.3.14.17 [SENSe:]POWer...
The [SENSe:]POWer... commands configure the optional receiver step attenuators
(see Chapter 4.7.31, "Receiver step attenuators", on page 309) and the wideband /
narrowband IF gain of the R&S ZNA.
See also [SENSe<Ch>:]SEGMent<Seg>:POWer:GAINcontrol on page 1490.
[SENSe<Ch>:]POWer:AGCMode<PhyPt>:MEASure....................................................... 1463
[SENSe<Ch>:]POWer:IFGain<PhyPt>:MEASure.............................................................1463
[SENSe<Ch>:]POWer:ATTenuation................................................................................1464
[SENSe<Ch>:]POWer:GAINcontrol................................................................................1464
[SENSe<Ch>:]POWer:GAINcontrol:ALL......................................................................... 1465
[SENSe<Ch>:]POWer:GAINcontrol:GLOBal................................................................... 1466
[SENSe<Ch>:]POWer:AGCMode<PhyPt>:MEASure <Mode>
[SENSe<Ch>:]POWer:IFGain<PhyPt>:MEASure <Mode>
These two equivalent commands activate manual gain control and select the IF gain in
the measurement channels (b-waves). The IF gain in the reference channel (a-waves)
is set automatically if not otherwise defined using [SENSe<Ch>:]POWer:
GAINcontrol.
This applies to the wideband signal path only.
Note:
These commands are replaced by [SENSe<Ch>:]POWer:GAINcontrol and
[SENSe<Ch>:]POWer:GAINcontrol:GLOBal. They are supported for compatibility
with FW versions < 1.5.
Suffix:
<Ch>
.
Channel number
<PhyPt> Test port number of the analyzer
Parameters:
<Mode> LDIStortion | LNOise
LDIStortion
0 dB gain, for high input levels
LNOise
10 dB gain, for low input levels
*RST: LDIS
Example:
*RST; :SENSe:POWer:IFG2:MEAS LNO; :SENSe:POWer:
IFG1:MEAS?
Optimize the received waves (measurement channel, b-waves)
at port 2 for small input levels and query the wideband / narrow-
band IF gain settings for the received waves at port 1. The
response is LDIS.