GUI reference
R&S
®
ZNA
512User Manual 1178.6462.02 ─ 29
Remote command:
CALCulate<Chn>:MARKer:MPEak:THReshold
CALCulate<Chn>:MARKer:MPEak:THReshold:STATe
Excursion Settings
Defines a minimum excursion for multiple peak searches and activates it.
If "Active", only peaks with an excursion above the configured "Excursion" value are
considered. By definition, the excursion of a peak is the smaller of the absolute differ-
ences in measured values from the adjoining peaks of opposite polarity.
The unit is derived from the active trace format and cannot be modified. Changing the
trace format resets the "Excursion" to a format-specific default value.
Remote command:
CALCulate<Chn>:MARKer:MPEak:EXCursion
CALCulate<Chn>:MARKer:MPEak:EXCursion:STATe
5.7.5 Target Search tab
The "Target Search" functions use markers to locate trace points with a specific
response value ("Target Value"). The functions are unavailable if the active trace con-
tains no markers (e.g. after "All Markers Off").
Some of the "Target Search" functions are equal to other marker search functions.
Refer to the following sections:
●
Chapter 5.7.3.2, "Search Range dialog", on page 506
●
"Tracking" on page 506
Target Value
Specifies the target value for the search.
Marker softtool