6 Remote control
This chapter provides instructions on how to set up the analyzer for remote control, a
general introduction to remote control of programmable instruments, and the descrip-
tion of the analyzer's remote control concept. For reference information about all
remote control commands implemented by the instrument, complemented by compre-
hensive program examples, refer to Chapter 7, "Command reference", on page 968.
For additional information on remote control of network analyzers, see the following
documents available from the Rohde & Schwarz website:
Remote control via SCPI
1EF62: Hints and Tricks for Remote Control of Spectrum and Network Analyzers
1MA171: How to use Rohde & Schwarz Instruments in MATLAB
1MA208: Fast Remote Instrument Control with HiSLIP
6.1 Introduction to remote control
The instrument offers different interfaces for remote control:
LAN
Analyzers connected to a LAN can be remote-controlled via the RSIB, VXI-11, or
HiSLIP protocols. The LAN connector is on the rear panel of the instrument (see
Chapter 3.2.2, "Rear panel", on page 41). A VISA installation on the remote control
PC is required.
USB
The R&S ZNA can also be remote-controlled via USB. The USB Device connector
is on the rear panel of the instrument. A VISA installation on the remote control PC
is required.
GPIB
The R&S ZNA offers a GPIB bus interface according to standard IEC 625.1/IEEE
488.1. The GPIB bus connector is on the rear panel of the instrument. The
R&S ZNA can be remote-controlled via GPIB.
The network analyzer can itself act as a master and control external devices via
LAN, USB, or GPIB. A VISA installation on the analyzer is a prerequisite for this
type of remote control. The RS VISA library is installed with the VNA firmware.
To control external devices via USB, the "IVI Visa Shared Components" must
be installed in addition. You can easily install it from the "Start" menu of your
analyzer.
To control external devices via GPIB, the built-in GPIB interface can be used.
An additional USB-to-IEC/IEEE adapter is only required in case that you want
to control the R&S ZNA via GPIB at the same time.