GUI reference
R&S
®
ZNA
761User Manual 1178.6462.02 ─ 29
●
Chapter 5.14.5.8, "EZD Advanced Settings", on page 741
Page 2: Measure / Load and Apply
The second page of the "Deembedding Assistant" dock widget allows you to:
●
Measure one or more test coupons, or load their S-parameter data from file
●
Measure DUT + test fixture
●
Send the measured/loaded data to the selected fixture tool and apply the calcula-
ted deembedding
If you select Use Same Coupon Left and Right on the topology page, then only one set
of test coupons can be measured (or loaded from file). The results are used for both
sides of the DUT.
With two coupons, "Coupon A" is used to deembed the left-hand side of the DUT and
"Coupon B" is used to deembed the right-hand side.
Coupon A / Coupon B section
In the "Coupon A" and "Coupon B" section, you can select one or more test coupons
and, for each of them, either measure its S-parameters at selected logical ports or load
them from a Touchstone file.
Depending on the selected DUT, a different set of test coupon types is supported.
Offset Embed softtool