EasyManua.ls Logo

Rohde & Schwarz R&S ZNA Series - 7.3.14.4 [SENSe:]CONVerter

Rohde & Schwarz R&S ZNA Series
1849 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command reference
R&S
®
ZNA
1329User Manual 1178.6462.02 ─ 29
Parameters:
<Address> String value with DLL-specific syntax and semantics. See the
docs of your DLL for details.
Parameters for setting and query:
<DllName> Name of a loaded DLL (see [SENSe:]CDLL:LIST?)
Lowercase string, without dll extension
<Task> Task type (see [SENSe:]CDLL:LIST:TASK?)
Manual operation: See "Configure Device Adress" on page 405
7.3.14.4
[SENSe:]CONVerter
Commands to set up frequency converters.
[SENSe:]CONVerter<Port>:CSLoss............................................................................... 1329
[SENSe:]CONVerter<Port>:CSSLope.............................................................................1330
[SENSe:]CONVerter:DEFinition:CATalog?.......................................................................1330
[SENSe:]CONVerter:DEFinition:COUNt?........................................................................ 1330
[SENSe:]CONVerter:DEFinition:DEFine..........................................................................1330
[SENSe:]CONVerter:DEFinition:DELete..........................................................................1331
[SENSe:]CONVerter:DEFinition:FREQuency...................................................................1331
[SENSe:]CONVerter:DEFinition:IFRequency...................................................................1332
[SENSe:]CONVerter:DEFinition:LMUL............................................................................1332
[SENSe:]CONVerter:DEFinition:LPOWer........................................................................1332
[SENSe:]CONVerter:DEFinition:LPOWer:OFFSet............................................................1332
[SENSe:]CONVerter:DEFinition:MPOWer....................................................................... 1333
[SENSe:]CONVerter:DEFinition:SMUL........................................................................... 1333
[SENSe:]CONVerter:DEFinition:SPOWer........................................................................1333
[SENSe:]CONVerter:DEFinition:SPOWer:OFFSet........................................................... 1334
[SENSe:]CONVerter<Port>:IFPort..................................................................................1334
[SENSe:]CONVerter<Port>:IFRequency......................................................................... 1334
[SENSe:]CONVerter<Port>:LOLoss............................................................................... 1335
[SENSe:]CONVerter<Port>:LOPort................................................................................ 1335
[SENSe:]CONVerter<Port>:RFLoss............................................................................... 1336
[SENSe:]CONVerter<Port>:RFPort?.............................................................................. 1336
[SENSe:]CONVerter<Port>:RFSLope.............................................................................1336
[SENSe:]CONVerter:SPLitter<Port>:LOPort....................................................................1336
[SENSe:]CONVerter:SPLitter<Port>:LOSS..................................................................... 1337
[SENSe:]CONVerter<Port>:STATe................................................................................. 1337
[SENSe:]CONVerter<Port>:CSLoss <Loss>
Default cable (and splitter) loss for the local port of converter <Port>.
Suffix:
<Port>
.
Port number
Parameters:
<Loss> Default unit: dB
Options: R&S ZNA-K8