GUI reference
R&S
®
ZNA
352User Manual 1178.6462.02 ─ 29
Remote command:
CALCulate<Ch>:PARameter:MEASure "<Trace_Name>", "IMB<i>-<j><k>"
| "IMB<j><k>-<i>"
CALCulate<Ch>:PARameter:SDEFine "<Trace_Name>", "IMB<i>-<j><k>"
| "IMB<j><k>-<i>"
5.2.2.5 Balanced Ports dialog
The "Balanced Ports" dialog allows you to enable/disable physical ports and to define
logical ports (balanced or unbalanced) in the active channel.
Access: Channel – [Channel Config] > "Port Config" > "Balanced Ports..."
Background information
Refer to the following sections:
●
Chapter 4.3.6, "Unbalance-balance conversion", on page 161
●
Chapter 4.3.6.1, "Balanced port configurations", on page 162
●
Chapter 4.3.2, "Reference impedances", on page 152
●
Chapter 4.7.5, "True differential mode", on page 277
Predefined Config tab
The "Predefined Config" tab of the "Balanced Ports" dialog provides the most com-
monly used logical port configurations of the analyzer.
This tab is hidden if a switch matrix is configured.
Meas softtool