5.14.11.1 Controls on the Deembed Assistant tab
Overview
This button is available on all "Offset Embed" softtool tabs. It opens the Overview panel
in the Offset Embed dock widget.
Fixture Tool/Tool Info
The "Fixture Tool" combo-box allows you to select the third-party fixture modeling tool
to be used with the deembedding assistant (see Chapter 4.6.2.9, "Fixture modeling
and deembedding", on page 242).
Use the "Tool Info" button to get additional information about the selected tool.
Remote command:
CALCulate:FMODel:DEASsistant:TOOL
Timestamp Filenames
If "Timestamp Filenames" is checked, the names of subsequently generated "Test Cou-
pon" and "DUT + Test Fixture" files are prefixed with the current date and time.
Remote command:
CALCulate:FMODel:REName
Show Remeasure Warnings
If checked, the "Coupon" and "DUT + Test Fixture" measurements raise warnings, if
the measurement is repeated with different ports.
This setting is global.