EasyManua.ls Logo

Rohde & Schwarz R&S ZNA Series - 7.3.15.6 SOURce:POWer:ALC...

Rohde & Schwarz R&S ZNA Series
1849 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command reference
R&S
®
ZNA
1542User Manual 1178.6462.02 ─ 29
SOURce:GROup:SIMultaneous:FOFFset:MOFFSet:
DVALue 0 MHz
Set minimum frequency offset for frequency shifted parallel mea-
surement to 0 MHz.
:SOURce:GROup:SIMultaneous:FOFFset:MOFFset:MODE
BANDwidth
:SOURce:GROup:SIMultaneous:FOFFset:MOFFset:
BWFactor 100
Set the minimum frequency offset for frequency shifted parallel
measurement to at least 100 times the measurement bandwidth
Manual operation: See "Parallel Measurement with Frequency Offset" on page 685
7.3.15.6 SOURce:POWer:ALC...
The following commands set up the automatic level control (ALC).
SOURce<Ch>:POWer:ALC:AUBW................................................................................ 1542
SOURce<Ch>:POWer:ALC:BANDwidth......................................................................... 1543
SOURce<Ch>:POWer<Pt>:ALC:CLAMp........................................................................ 1543
SOURce<Ch>:POWer<Pt>:ALC:COUPle....................................................................... 1544
SOURce<Ch>:POWer:ALC:CSTate............................................................................... 1544
SOURce<Ch>:POWer<Pt>:ALC:OPTimize..................................................................... 1544
SOURce<Ch>:POWer<Pt>:ALC:PIParameter.................................................................1545
SOURce<Ch>:POWer:ALC:PIParameter:ASETtling........................................................ 1545
SOURce<Ch>:POWer:ALC:PIParameter:CTIMe............................................................. 1546
SOURce<Ch>:POWer<Pt>:ALC:PIParameter:GAIN........................................................ 1546
SOURce<Ch>:POWer<Pt>:ALC:PIParameter:ITIMe........................................................1546
SOURce<Ch>:POWer<Pt>:ALC:RANGe........................................................................1547
SOURce<Ch>:POWer<Pt>:ALC:RECeiver..................................................................... 1547
SOURce<Ch>:POWer<Pt>:ALC:SOFFset...................................................................... 1547
SOURce<Ch>:POWer<Pt>:ALC[:STATe]........................................................................ 1548
SOURce<Ch>:POWer:ALC:STOLerance........................................................................1548
SOURce<Ch>:POWer<Pt>:ALC:TPOWer.......................................................................1549
SOURce<Ch>:POWer<Pt>:ALC:TPOWer:DEFault.......................................................... 1549
SOURce<Ch>:POWer<Pt>:ALC:VNETwork....................................................................1549
SOURce<Ch>:POWer:ALC:AUBW <Boolean>
Enables or disables automatic IF bandwidth setting for the ALC path in channel <Ch>.
Set SOURce<Ch>:POWer:ALC:AUBW to OFF and use SOURce<Ch>:POWer:ALC:
BANDwidth to set the bandwidth manually.
Suffix:
<Ch>
.
Channel number
Parameters:
<Boolean> ON (1)
Enables automatic bandwidth setting for ALC in channel <Ch>.
OFF (0)
Disables automatic bandwidth setting for ALC in channel <Ch>.
SCPI command reference

Table of Contents

Related product manuals