Command reference
R&S
®
ZNA
1716User Manual 1178.6462.02 ─ 29
[SENSe<Ch>:]FREQuency:IMODulation:TTOutput <TwoToneOutput>
Selects the source for the two tone output signal for intermodulation measurements.
Deprecated, superseded by SOURce<Ch>:COMBiner.
Suffix:
<Ch>
.
Channel number.
Parameters:
<TwoToneOutput> PORT | EDEVice
PORT
Analyzer port 1.
Requires a R&S ZNA with Direct generator/receiver access or
with Internal combiner.
EDEVice
External combiner
*RST: EDEVice
Example: See [SENSe<Ch>:]FREQuency:IMODulation:LTONe.
[SENSe<Ch>:]FREQuency:MODE <FreqSweep>
Selects the sweep type and defines which set of commands controls the stimulus fre-
quency.
Tip: The command [SENSe<Ch>:]SWEep:TYPE provides a complete list of sweep
types.
Suffix:
<Ch>
.
Channel number
Parameters:
<FreqSweep> CW | FIXed | SWEep | SEGMent | PULSe
Linear or logarithmic frequency sweep, depending on the
selected spacing ([SENSe<Ch>:]SWEep:SPACing LINear |
LOGarithmic). The frequency range is set via [SENSe<Ch>:
]FREQuency:STARt etc.
Example:
FREQ:MODE CW
Activate a time sweep.
FREQ:CW 100MHz
Set the CW frequency to 100 MHz.
[SENSe<Ch>:]SEGMent<Seg>:CLEar
Deletes all sweep segments in the channel. The command is equivalent to
[SENSe<Ch>:]SEGMent<Seg>:DELete:ALL.
Suffix:
<Ch>
.
Channel number
R&S ZVR/ZVABT compatible commands