Command reference
R&S
®
ZNA
989User Manual 1178.6462.02 ─ 29
CALCulate<Chn>:EYE:MASK:SHAPe:POLYgon:VERTical...............................................1006
CALCulate<Chn>:EYE:MASK:SHOW............................................................................ 1006
CALCulate<Chn>:EYE:MASK:STATe............................................................................. 1006
CALCulate<Chn>:EYE:MASK:VIOLation:RATE...............................................................1007
CALCulate<Chn>:EYE:MASK:VIOLation:TOLerance....................................................... 1007
CALCulate<Chn>:EYE:MEASurement:DATA?.................................................................1007
CALCulate<Chn>:EYE:MEASurement:STATe................................................................. 1009
CALCulate<Chn>:EYE:MEASurement:TTIMe:THReshold................................................ 1009
CALCulate<Chn>:EYE:NOISe:RMS...............................................................................1009
CALCulate<Chn>:EYE:NOISe:STATe.............................................................................1010
CALCulate<Chn>:EYE:STATe....................................................................................... 1010
CALCulate<Chn>:EYE:STIMulus:ENCoder.....................................................................1010
CALCulate<Chn>:EYE:STIMulus:LOWPass....................................................................1011
CALCulate<Chn>:EYE:STIMulus:SCRambler..................................................................1011
CALCulate<Chn>:EYE:VIEW.........................................................................................1011
CALCulate<Chn>:EYE:DUT:MODE <DUTMode>
Allows to (temporarily) switch between the measured DUT and an ideal one (with flat
frequency response) in the related eye diagram.
This command will raise an execution error if the active trace in the selected channel is
not an eye diagram.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<DUTMode> IDEal | MEASured
Options: R&S ZNA-K20
Manual operation: See "Mode" on page 819
CALCulate<Chn>:EYE:EMPHasis:CURSor:POST<1|2> <Weight>
Sets the weights of the post-cursor taps for the pre-emphasis FIR filter in the calcula-
tion chain of the related eye diagram.
This command will raise an execution error if the active trace in the selected channel is
not an eye diagram.
Emphasis in the generator simulation for eye diagram measurements is enabled using
CALCulate<Chn>:EYE:EMPHasis:STATe.
Suffix:
<Chn>
.
Channel number used to identify the active trace
<1|2> 1 for the "Post 1" filter tap, 2 for the "Post 2" filter tap.
Parameters:
<Weight> Weight relative to the "Cursor" tap
*RST: 0 dB
Default unit: dB
SCPI command reference

Table of Contents