1002 HEIDENHAIN Technical Manual iTNC 530 HSCI
FUNCTION SCOPE STORE
If you call this function that does not contain parameters, the storage of the
data in the buffer of the oscilloscope is forced from within the NC program.
If a trigger condition has been fulfilled before the STORE function is called, the
results for the trigger condition are written to the file indicated in RESULT.
You need to stop recording before you can save the data.
This function releases the internal oscilloscope, and therefore the
oscilloscope can be started again with the OSCI soft key.
Set Reset
M4627 Trigger condition for integrated
oscilloscope fulfilled
NC PLC
M4628 Recording of the integrated
oscilloscope ended
NC PLC