1538 HEIDENHAIN Technical Manual iTNC 530 HSCI
Non-HEIDENHAIN
touch probes
Module 9135 Switch on the 3-D touch probe
With Module 9135 you can switch on or retrigger certain 3-D touch probes. If
the touch probe is already switched on, the module call has no effect. If
M4056 is set and the touch probe does not provide a ready signal, the feed-
rate enabling (M4563) is reset.
Call:
CM 9135
Error code:
Module 9136 Switch the touch probe on/off
Module 9136 switches a touch probe at X12 on or off once. If the touch probe
does not supply a ready signal, and if M4056 is set (NC stop for deflected
touch probe in all operating modes), the feed-rate enable is reset.
After Module 9136 is called the first time, the NC does not output any more
on/off signals, meaning that the touch probe is now solely controlled by the
PLC program.
Call:
PS B/W/D/K <Touch probe state>
0: Switch off touch probe
1: Switch on touch probe
CM 9136
Error code:
Marker Value Meaning
M4203 0 No error
1 Error in module run
Marker Value Meaning
M4203 0 Touch probe on or off
1 Error code in W1022
W1022 1 Invalid touch probe state

Table of Contents