1558 HEIDENHAIN Technical Manual iTNC 530 HSCI
Individual tooth
measurement
The TNC attempts to maintain the tolerance from MP6510.0 during the tooth
search for individual tooth measurement. At the same time MP6510.0 is used
to calculate the probing feed rate.
If the tolerance from MP6510.0 cannot be maintained during the tooth search,
e.g. due to the missing spindle accuracy, the TNC attempts to maintain the
tolerance from MP6510.1. If this also cannot be maintained, the error
message Tolerance in MP6510 too small appears.
Enter the first maximum measuring error in MP6510.0.
Enter the second maximum measuring error in MP6510.1.
MP6510 Maximum permissible measuring error for tool
measurement with rotating tool
Input: 0.002 to 0.999 [mm]
MP6510.0 First measurement error
MP6510.1 Second measurement error
Monitoring of the
rotary axes and
secondary linear
axes
To ensure that the rotary axes and the secondary linear axes are always in a
defined position during the tool measuring cycles:
In MP6585, enter the axes to be monitored.
In MP6586.x, enter the reference coordinate at which the axis should be
located during the tool measuring cycles.
If, during activated monitoring, the nominal position does not match the
position from MP6586.x, an error message is displayed.
MP6585 Monitoring the position of the rotary and additional linear
axes during the tool measurement cycles
Format: %xxxxxx
Input: 0: Axis is not monitored
1: Axis is monitored
Bit 0 – A axis
Bit 1 – B axis
Bit 2 – C axis
Bit 3 – U axis
Bit 4 – V axis
Bit 5 – W axis
MP6586 Ref. coordinate for monitoring the position of the rotary
and additional linear axes during the tool measurement
cycles
Input: –99 999.9999 to +99 999.9999 [mm] or [°]
MP6586.0 A axis
MP6586.1 B axis
MP6586.2 C axis
MP6586.3 U axis
MP6586.4 V axis
MP6586.5 W axis