884 HEIDENHAIN Technical Manual iTNC 530 HSCI
Setting of MP2190:
MP2160 default setting made
Regenerative module
(e.g. UVR 150D)?
MP2190 = 650 (4)
YES
Stationary line voltage stable?
MP2190 = smallest value of stationary
DC-link voltage (6)
No
– Calculation of minimum line voltage (5)
– Series reactor taken into account
– Line voltage at machine installation site
taken into account
MP2190 = actual
DC-link voltage
No
Line voltage stable under load?
MP2190 = smallest value of dynamic
DC-link voltage (7)
No
MP2190 setting done
YES
YES