1452 HEIDENHAIN Technical Manual iTNC 530 HSCI
Module 9064 Status information about collision monitoring
With Module 9064 you interrogate whether collision monitoring is active in the
currently selected operating mode. The module was expanded by Mode 1.
Constraints:
Collision monitoring is not active in the Reference Run mode.
Call:
PS B/W/D/K <Mode>
0: Configured status (depends on module 9063 and soft
key)
1: Status in the current mode of operation (0 in Reference
Run mode)
CM 9064
PL B/W/D <Status information>
0: Monitoring not active
1: Monitoring active
Error code:
Marker Value Meaning
M4203 0 Status ascertained
1 Error code in W1022
W1022 1 Invalid value for mode