140 HEIDENHAIN Technical Manual iTNC 530 HSCI
Type The iTNC 530 HSCI is shipped with the following NC software:
Due to restrictions on the export of the iTNC 530, HEIDENHAIN can also
supply a special export version. This export version differs from the standard
control through the installed NC software type. HEIDENHAIN releases a new
NC software type whenever it introduces extensive new functions.
2.7.2 PLC software
The PLC software is stored on the hard disk or the solid state disk of the iTNC.
You can order a PLC basic program directly from HEIDENHAIN. With the PLC
development software PLCdesignNT, the PLC program can very easily be
adapted to the requirements of the machine.
2.7.3 Additional control loops or software options
The system identification key (SIK) determines the available software options
and the number of available control loops on the iTNC 530 HSCI. Each
MC 6xxx can clearly be identified by the system identification key (SIK). You
will find the SIK number on the outside of the MC 6xxx housing (below the ID
label) and on the SIK board. To install the SIK, see "Handling the HDR hard disk"
on page 195.
There are different versions of SIKs for the iTNC 530 HSCI, depending on the
MC main computer used and the number of required control loops. Additional
control loops (up to the maximum permissible number) can be enabled at any
later time. See "SIK MC 62xx, MC 63xx" on page 82.
Software options can be used to adapt the scope of functions of the control to
the respective needs and applications. See "Software options" on page 136.
If you want the code number for enabling additional control loops or software
options, please contact HEIDENHAIN for the code number. HEIDENHAIN can
give you the code number after you state your SIK number.
In order to enable additional control loops or software options, proceed as
follows:
While in the Programming and Editing operating mode, press the MOD key.
Enter the code number SIK and confirm your entry with the ENT key.
Standard Export Comment
606420-xx 606421-xx iTNC 530 HSCI
606422-xx 606423-xx iTNC 530 HSCI
Note
If you replace the MC 6xxx, you must also replace the SIK in order to ensure
that the enabled control loops and software options will also be enabled on
the new hardware.