1416 HEIDENHAIN Technical Manual iTNC 530 HSCI
Starting the PLC
editor for tables
In the machining modes a table editor can be started:
Specify the lines and columns that are to be displayed.
You can provide the PLC editor only with tables with the file extensions .TAB
or .P. A temporary file with the name SYS:\TEMP\PLCTABED.TAB is saved.
With Modules 9240, 9241, 9245 and 9247 you can check this temporary file
before you place the edited data into the original table with Module 9251.
Enter the editable columns in the sequence in which they are to be
displayed.
Do not enter the line number! It is displayed automatically.
Separate the individual columns by a space character. If you have
transferred an empty string, all columns of the original table are displayed.
Enter the first and last line to be displayed on the screen. Line numbering
begins with zero. If you enter –1 as the last line, the table will be shown to
its end. If you release all lines and columns for editing, you can choose:
Whether lines can be deleted and inserted
Whether the original table should be edited directly
If you edit the original table directly, you cannot cancel the changes with
Module 9251.
If you do not edit the original table directly and the PLC program is recompiled
while the PLC editor is open, the editor will be closed without transferring the
changes to the original table.
If the END key or the END soft key is pressed while the PLC editor is opened,
the NC sets M4159. The PLC editor is not closed by the NC. It must be closed
by the PLC with Module 9251.
M4159 is reset when Module 9250 is called.
With Module 9035 you can request the active line in the PLC editor.