1542 HEIDENHAIN Technical Manual iTNC 530 HSCI
Probing from
OEM cycles
With FN17:SYSWRITE ID990 NR1 adjust the approach behavior. If the input
value = 0, the setup clearance from MP6140 and the effective radius are
accounted for. If the input value > 0, the workpiece is approached as if the
effective radius and set-up clearance were zero. This function can be used,
for example, for measuring small holes.
If you are using a TS 440 or TS 640 infrared touch probe, then before starting
the probing cycle, you should orient the touch probe to the position at which
it was calibrated. Define an M function for automatically orienting the probe to
this position before probing. If the ready signal of the touch probe is already
available, the touch probe is not oriented.
In MP6161, enter the number of the M function.
Enter the orientation angle in MP6162.
In MP6163, enter a minimum angle difference for orienting with the defined
M function..
MP6161 M function for orienting the touch probe before every
measuring process
Input: –1: Spindle orientation directly by the NC
0: Function inactive
1 to 999: Number of the M function
MP6162 Orientation angle
Input: 0 to 359.9999 [°]
MP6163 Minimum difference between the current spindle angle and
MP6162 before executing an oriented spindle stop
Input: 0 to 3.0000 [°]
Orientieren,wenn MP6163 < Aktueller Spindelwinkel MP6162–()