July 2013 4.3 Input and output of machine parameters 491
Module 9314 Activate/Deactivate machine parameters
PLC module 9314 is used to axis-specifically activate/deactivate other values
from machine parameters during run time.
Condition:
The module transmits the information at the end of a PLC cycle.
After the PLC program has been restarted, the module will no longer be
effective and the original configuration will become active again.
HEIDENHAIN recommends using power limiting (mode 0) via MP2393.x
only for spindles. Power limiting for axes might cause positioning errors.
Call:
PS K/B/W/D <Bit mask for axes/spindles>
Bit for axis/spindle = 1: Value from MPxxxx.y is active
Bit for axis/spindle = 0: Value from MPxxxx.y is not active
PS K/B/W/D <Mode>
0: Activation/Deactivation of power limiting (MP2393.x)
CM 9314
Error code:
Marker Value Meaning
M4203 0 No error
1 Error code in W1022
W1022 1 Invalid value for this mode is active
24 Call was not from a cyclic program