188 HEIDENHAIN Technical Manual iTNC 530 HSCI
3.2.3 Limit values for ambient conditions
HEIDENHAIN specifies the range of application 2 for the use of its control
products.
Furthermore, the following limit values apply:
3.2.4 Installation elevation
The maximum elevation for installation is 3000 m above sea level.
Characteristic
values during
operation:
Limit values to be
maintained
Standard to be
complied with
Vibration ± 0.075 mm, 10 Hz to 41 Hz;
5 m/s2, 41 Hz to 500 Hz;
DIN EN 60068-2-6
Shock 50 m/s2, 11 ms DIN EN 60068-2-27
Relative air humidity 75 % in continuous
operation;
95% for not more than 30
days a year (randomly
distributed)
IP protection IP 54 for
HW, TFT, MB, TE
DIN EN 60529
ESD 61000-4-2 Severity level 3 DIN EN 6100-4-2
RF field 61000-4-3 Severity level 3 DIN EN 6100-4-3
Burst 61000-4-4 Severity level 3 DIN EN 6100-4-4
Surge 61000-4-5 Severity level 3 DIN EN 6100-4-5
Conducted
disturbances
Severity level 3 DIN EN 6100-4-6

Table of Contents