1420 HEIDENHAIN Technical Manual iTNC 530 HSCI
Error code:
Module 9241 Close a file
With this module you close a file that has been opened with Module 9240. You
must close the file in the process (submit job or spawn job) in which you
opened it.
Call:
PS D <File handle>
Number from Module 9240
CM 9241
Error code:
Marker Value Meaning
M4203 0 File was opened
1 Error code in W1022
W1022 1 Impermissible mode
3 Incorrect string number
7 File could not be opened
20 Module was not called in a spawn or submit job
Marker Value Meaning
M4203 0 File was closed
1 Error code in W1022
W1022 2 Incorrect file handle
20 Module was not called in a spawn or submit job