8.7 Pallet management
Configuring a pallet
table
The pallet table is a "freely definable table":
Define the prototype in the directory PLC:\PROTO with the file name
extension .P.
Create the prototype.
(See "Freely definable tables" on page8 – 1409)
If you have more than one prototype with the file name extension .P, a menu
for format selection will appear when you create a pallet table. Your PLC
program must be adapted to the various formats.
The COPY SAMPLE FILES soft key copies prototypes for the pallet tables into
the directory PLC:\PROTO.
The appropriate prototypes are offered when you create a new pallet table. If
you do not want this to happen, delete unnecessary prototypes from the
PLC:\PROTO directory. Then only existing prototypes are displayed.
PROTOTYP.P = Standard prototype (PAL/PGM, NAME, DATUM, X, Y, Z)
PROTO_TO.P = Prototype for tool-oriented machining
PROTOPR.P = Standard prototype for preset tables
PRO_TOPR.P = Prototype for tool-oriented machining with preset tables