July 2013 8.1 Display and operation 1219
The following graphic schematically shows the principle of adaptive feed
control:
1: Feed rate
2: Air cut
3: Beginning of machining
4: Feed-rate calculation during machining
5: Feed rate calculated by AFC
6: Feed rate programmed in the NC program
7: Cutting depth
8: Workpiece
Operating states
of AFC
The two main operating states of adaptive feed control are Learning and
Controlling and Monitoring.