July 2013 3.26 Touch probes 313
3.26 Touch probes
The following touch probes can be connected to the iTNC 530 HSCI:
TS 220, touch-trigger probe with cable connection for workpiece setup and
measurement during machining
TS 440, TS 444, TS 640, TS 642, TS 740, touch-trigger probes with infrared
transmission for workpiece setup and measurement during machining
TT 130, TT 140, TT 449 touch probes for tool measurement
For suitable connecting cables, see "Cable Overview" at the end of the
chapter.
X112/X113:
Triggering touch
probe
Note
The touch probes are connected to the PLB 620x PLC system module or
UEC 11x at X112 (TS) and X113 (TT).
Note
For the PLB 62xx up to and including variant -02, please note:
Variant -02:
To connect a TT touch probe to the PLB 62xx, you have to connect the
touch probe adapter, ID 667674-01 to X113, see "Adapter for connection of
a TT touch probe to X113" on page 316. The adapter is supplied with the PL.
Note
The touch probes are connected to the PLB 620x PLC system module or
UEC 11x at X112 (TS) and X113 (TT).
Note
For the PLB 62xx up to variant -02, please note:
To connect a TT touch probe to the iTNC 530 HSCI, you have to connect
the touch probe adapter, ID 667674-01, to X113.

Table of Contents

Other manuals for HEIDENHAIN iTNC 530 HSCI

Related product manuals