1172 HEIDENHAIN Technical Manual iTNC 530 HSCI
Module 9192 Read the operating times
You read the current value of an operating time. The current value is
transferred in seconds. If the value is greater than 2 147 483 648 (approx. 69
years), a negative number will be transferred.
Call:
PS B/W/D/K <Number of the operating time>
–3: Control on
–2: Machine on
–1: Program run
0 to 12: PLC operating times 1 to 13
CM 9192
PL B/W/D <Current time [s]>
–1: Error
Error code:
Module 9193 Set the operating times
You overwrite the current value of the operating time. The old value is lost
irretrievably.
The time for Control on cannot be overwritten.
Transfer all values greater than 2 147 483 648 (approx. 69 years) as negative
numbers.
Constraint:
So as not to impair the behavior of the overall system, the module may only
be used for re-initializing the machine times, and may not be called too
often. The module (and therefore the calling submit or spawn job) waits for
acknowledgment.
Call:
PS B/W/D/K <Number of the operating time>
–2: Machine on
–1: Program run
0 to 12: PLC operating times 1 to 13
PS B/W/D/K <New time [s]>
CM 9193
Error code:
Marker Value Meaning
M4203 0 PLC operating time started
1 Incorrect transfer value, or module was not called in a
spawn or submit job
Marker Value Meaning
M4203 0 Operating time was overwritten
1 Incorrect transfer value, or module was not called in a
spawn or submit job