July 2013 3.7 iTNC 530 HSCI connection overview 221
3.7.13 PLB 62xx
3.7.14 PLB 62xx FS
System module
Pin layout Connector Function Page
X500 HSCI output 208
X502 HSCI input 208
X9 Safety-related PLC inputs/outputs 273
X2 Reserved –
X3 +24V NC, +24V PLC power supply 267
X112 TS or TT touch trigger probe 313
X113 TS or TT touch trigger probe 313
Diagnosis: For meanings of the LEDs, see page 268
System module
Pin layout Connector Function Page
X500 HSCI output 208
X502 HSCI input 208
X9 Safety-related PLC inputs/outputs 274
X2 Reserved –
X3 +24V NC, +24V PLC power supply 267
X112 TS or TT touch trigger probe 313
X113 TS or TT touch trigger probe 313
On the PL 62xx FS, the I/O terminals of connector X9 are dual-channel
terminals and can therefore be used for safety-related applications.
PLD-Hs with functional safety (FS) can be used only in the PL 62xx FS. A
safety-related PLD must not be inserted after a PLD without FS, or after an
empty slot. Safety-related PLDs must be inserted—one after the other—
into successive slots without interruption (empty slot). The normal PLDs or
PLAs must not be inserted until all PLDs with FS have been inserted.
Diagnosis: For meanings of the LEDs, see page 268
X502
X500
X9
X2
X112
X113
X3
S
a
f
e
t
y